How Can We Help?
< All Topics
Print

401 – TCU Data Fields

FieldColumnDescriptionDefaultComments
1AIndex Number000000System Generated
2BDate and Time2021-11-17 11:30Moment of recording the line.
3CType30 = Cold Boot, 1 = Power Up, 2 = AWB/Container no. modified, 3 = Values.
4DAirway Bill Number12500010010If Type = 1,2,3.
5EContainer Number10010If Type = 1,2,3.
6FPower Fail Y/NNBattery < 4.5 V, logging stopped.
7GBattery FailNBattery < 6.0 V, cooling stopped.
8HFan 1 on Y/NYFan 1 active at moment of logging.
9IFan 2 on Y/NYFan 2 active at moment of logging.
10JMemory ErrorNSettings Memory corrupted.
11KTemp 1 failure Y/NNTemp 1 pt-100 does not function correctly.
12LTemp 2 failure Y/NNTemp 2 pt-100 does not function correctly.
13MTemp 1 unstable Y/NNTemp 1 differed more than 10 C in 5 sec.
14NTemp 2 unstable Y/NNTemp 2 differed more than 10 C in 5 sec.
15OFan 1 failure Y/NNFan 1 current to high or to low.
16PFan 2 failure Y/NNFan 2 current to high or to low.
17QFahrenheit Y/NNDevice displays value in Fahrenheit.
18RTwo FansYIf N only Fan 1 in use, if Y both fans.
19SRatio %50.0%Calculated Temp = T1 x Ratio + T2/100.
20TSet Point temperature4.0Set point temperature.
21UTemperature Box (c)0.0Internal temperature inside TCU.
22VTemperature-temp-10.0Temperature 1 sensor value.
23WTemperature-temp-20.0Temperature 2 sensor value.
24XCalculated temp0.0Calculated temperature - see Ratio.
25YBattery Voltage 00.0Voltage (V).
26ZFan 1 average current000Average since last log storage.
27AAFan 2 average current000Average since last log storage.
28ABFan 1 on time (s) 000000Fan 1 runtime in seconds since last log storage.
29ACFan 2 on time (s)000000Fan 2 runtime in seconds since last log storage.
30ADTCU firmware version numberp/n 1375-10-4xxx only.
31AEBattery back serial numberp/n 1375-10-4xxx only.
32AFBattery pack firmware numberp/n 1375-10-4xxx only.
33AGChemistry 0 = NiMH0p/n 1375-10-4xxx only.
34AHCapacity in mAhp/n 1375-10-4xxx only.
35AIRecommended maximum charge cycles350Internal use only
36AJStatus-Internal use only
37AKBattery voltage in units of 0.1V00.0Internal use only
38ALCharge level %000Internal use only
39AMBattery pack temperature in C0.00Internal use only
40ANNumber of charge cycles000Internal use only
41AONumber of deep discharge cycles000Internal use only
42APLast charge level in % at start of charging00.0Internal use only
43AQLast charge time in minutes000Internal use only
Values 1 - 30 - recorded by p/n 735.100.000 and 1375-10-4xxx.
Values 31 - 43 recorded by 1375-10-4xxx only.
Previous 401 – BA TCU Settings